HY2550
HY2550 Series Features
- High-accuracy voltage detection circuit for 3/4/5 Cell Application
- Charge overcurrent protection
- Three-level discharge overcurrent protection
- Delay time:
- Delay times are set by external capacitors respectively at CCT pin and CDT pin for overcharge detection, /charge overcurrent detection and overdischarge detection/discharge overcurrent detection voltage 1
- Delay times are set internally for discharge overcurrent detection voltage 2 (1ms) and discharge overcurrent detection 3 (300μs)
- Cell number selection: SEL pin is used to select either 3 cells or 4 cells in use. SEL5 pin is used to select 5 cells in use when SEL pin is also set to “1”
- Charge/discharge operation can be controlled via the CTL pin
- 0V Battery Charge inhibition
- High voltage withstand range: Absolute maximum rated level:28V
- Wide operating temperature range:-40℃ to +85℃
- Low current consumption:
- Operation mode 12μA typ., 30μA max. (VCn = 3.5V)
- Power-down mode 1.2μA typ., 2.0μA max. (VCn = 2.0V)
- Small package:16-pin TSSOP
- Halogen free green product
Package Type TSSOP16L DataSheet
Product Name | Overcharge Detection Voltage VCU |
Overcharge Release Voltage VCR |
Overdischarge Detection Voltage VDL |
Overdischarge Release Voltage VDR |
Overcurrent Detection Voltage1 【VIOV1】 |
Overcurrent Detection Voltage2 【VIOV2】 |
Charge Overcurrent Detection Voltage VCIP |
0V Battery Charge Function V0CH |
---|---|---|---|---|---|---|---|---|
HY2550AA-T016-AC | 4.350 V | 4.150 V | 2.400 V | 3.000 V | 0.200 V | 0.500 V | -0.100 V | Available |
HY2550AB-T016-AC | 4.250 V | 4.150 V | 2.700 V | 3.000 V | 0.200 V | 0.500 V | -0.100 V | Available |
HY2550AC-T016-AC | 3.900 V | 3.800 V | 2.000 V | 2.500 V | 0.150 V | 0.500 V | -0.100 V | Available |
SelectionGuide